ATM-100A3-A-ER1
ATOM Solenoid interlock, normally closed (PTU), one connection, alternative circuit (Fortress), escape release inside


Betreff: ATM-100A3-A-ER1 ATOM Solenoid interlock, normally closed (PTU), one connection, alternative circuit (Fortress), escape release inside


General data

Item number
ITM-00542688
Functional type
ATOM Solenoid interlock, normally closed (PTU), one connection, alternative circuit (Fortress), escape release inside
Type designation
ATM-100A3-A-ER1

Safety data

Diagnostic coverage DC
Maximum 99% with appropriate monitoring
PFHd (EN ISO 13849)
4,16 x 10⁻⁹
Construction type (acc. to ISO 14119)
Type 2
Demand rate (acc. to IEC 62061)
High
Type of coding (according to EN ISO 14119)
High
Standards
ISO 14119, EN ISO 13849, IEC 61508, EN 60947-5-2, BS EN 62061
Category (EN ISO 13849-1:2015)
up to Category 4
SIL (acc. IEC 62061)
up to SIL3 CL3

Environmental conditions

operating environment
Indoor
Contamination level
2
Max. operating temperature
-20°C bis +55°C (-4°F bis +131°F) °C
Relative humidity
50% at 70°C
Altitude
2.000 m
Vibration resistance
Tested according to GS-ET-19 and EN 60947-5-2

Electrical data

Rated operating voltage Ue
24V DC (+10%, -15%) V
Rated insulation voltage Ui
60 V
Rated impulse withstand voltage Uimp
0,5 kV
Voltage drop Ud
< 3,5 V
Rated current (on 24 VDC)
400 mA
Current consumption
min. 100 mA
Rated conditional short-circuit
100 A
Power consumption when switched off
< 0,5 mA
Overvoltage category
Type 2
Electromagnetic Compatibility (EMC)
Complies with EN 60947-5-3
Compliance with UL requirements
The unit must be operated on an energy-limited circuit. circuit. The power supply requires a 4 A fuse.
Design / Connections
1 x M12 8-pin male connector
Function type safety outputs
2 x OSSD
pin assignment with SSP accessories cable
1
White - Safety input 1
2
Brown - UB
3
Green - Safety output 1
4
Yellow - Safety output 2
5
Grey - Diagnostic output On (door open)
6
Pink - safety entrance 2
7
Blue - GND
8
Red - Solenoid On (guard locking unlocked)
Response times
Safe response time
< 200 ms
Safe input "low" to safe output "low
< 25 ms
Guard locking unlocked until safe output "low"
< 200 ms
Safety functions
Safety function 1
Secure inputs on
Safety function 2
Protective device closed
Safety function 3
Safety guard kept closed
Safe state 1
1 OSSD output off
Safe state 2
Protective device closed

Mechanical data

Housing material
Passivated and painted zinc alloy to BSEN12844 ZA3 and stainless steel acc. to BS3146-2:1975 (ANC4B)
Mechanical service life
1.000.000 switching cycles
Locking force Fmax
5.000 N
Locking force FZh
6000 N
Maximum locking force F1max
12000 N
Minimally actuation radius
150 mm (see figure 5)
Maximum actuation frequenzy
720 switching cycles per hour

Electrical drawings

Pin assignment 1
Pin assignment 1

Drawings

Dimensions
Dimensions

Equipment