S16LDRB-H10-Q1A-Q2A-Q3A-Q4A

Your advantages

  • 14 I/O's as safety Inputs or redundant OSSD- Outputs
  • wireless Interface for safe communication, programming & diagnosis
  • IP65
  • 40mm width for aluminium safety fence systems

S14LDRB-H10-Q1A0-Q2A0-Q3A0-Q4A0
Safety Simplifier | without buttons & connections

With the Safety Simplifier we take safety where it is needed and we provide safety where it is needed with the Safety Simplifier and make it easier for you to develop user-friendly safety systems, such as on access doors. Simply connect up your sensors, locking systems or light curtains. Select the required push button and/or emergency stop button and you have a complete safety solution with analysis and diagnosis functions. his data is wirelessly transmitted via another Safety Simplifier or directly transmitted to your existing system in a fail-safe manner.

 

General data

Type designation
S14LDRB-H10-Q1A-Q2A-Q3A-Q4A
Item number
SP-X-89-000-04
Functional type
Safety PLC with safe wireless interface, internal antenna
Approvals
CE, TÜV
Safety-relevant data
 
CPU
 
- EN ISO 13849-1:2015
PLe
- EN ISO 13849-1:2015
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
2,12E-0,9
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel input
 
- EN ISO 13849-1:2015
PLe
- EN ISO 13849-1:2015
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
4,60E-09
- EN ISO 13849-1: 2008 TM [Year]
20
2-channel input
 
- EN ISO 13849-1:2015
PLe
- EN ISO 13849-1:2015
Category 2
- IEC 61508-2
SIL CL 2
- EN 62061 PFHD [1/h]
4,60E-09
- EN ISO 13849-1: 2008 TM [Year]
20
1-channel OSSD output
 
- EN ISO 13849-1:2015
PLd
- EN ISO 13849-1:2015
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
1,34E-09
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel OSSD Output
 
- EN ISO 13849-1:2015
PLe
- EN ISO 13849-1:2015
Category 4
- IEC 61508-2
SIL CL 3
- EN 62061 PFHD [1/h]
7,76E-09
- EN ISO 13849-1: 2008 TM [Year]
20
2- channel relais output
 
- EN ISO 13849-1:2015
PLe
- EN ISO 13849-1:2015
Category 4
- EN 62061 SIL CIL
SIL CL 3
- EN 62061 PFHD [1/h]
3,87E-09
EN ISO 13849-1: 2008 TM [Year]
20

Environmental conditions

Max. storage temperature
-20 °C ... +65 °C
Max. operating temperature
-20 °C ... +65 °C

Electrical data

Technical data wireless safety
 
- max. amount of safe wireless channels
16
Channels
 
- Channel 1
2405 MHz
- Channel 2
2410 MHz
- Channel 3
2415 MHz
- Channel 4
2420 MHz
- Channel 5
2425 MHz
- Channel 6
2430 MHz
- Channel 7
2435 MHz
- Channel 8
2440 MHz
- Channel 9
2445 MHz
- Channel 10
2450 MHz
- Channel 11
2455 MHz
- Channel 12
2460 MHz
- Channel 13
2465 MHz
- Channel 14
2470 MHz
- Channel 15
2475 MHz
- Channel 16
2480 MHz
- amount of clamps
32
Conductor cross section
 
- single wire
0,08 … 0,5 mm²
- fine wire
0,08 … 0,5 mm²
- fine wired (wire sleeve with plastic collar)
0,08 … 0,5 mm²
- fine wired (wire sleeve without plastic collar)
0,25 mm²
stripping length
5-6 mm
configurable In-/ Outputs
 
14 semiconductor In-/ Outputs with help of software configurable
Amount of safe inputs
max. 14
Amount of safe semi-conductors OSSD outputs
max. 14
Amount of semi-conductors auxilliary outputs
max. 14
Amount of semi-conductors clock outputs
max. 14
Input voltage
HIGH 75% of UB (adaptable with software) LOW 25% of UB (adaptable with Software)
Input current
HIGH 2,4 mA ... 3,8 mA LOW -2,5 mA ... 2,1 mA
Technical data safe OSSD outputs
 
Output type
PNP- semiconductor
Output voltage
Operating voltage UB -0,5 V
Seperate output current
max. 0,6 mA (with UB 24 V)
Total output current
max. 2 A (with UB 24 V)
Short-circuit proof
Yes
Technical data auxilliary outputs
 
Output type
PNP- semiconductor
Output voltage
Operating voltage UB -0,5 V
Seperate output current
max. 0,6 mA (with UB 24 V)
Total output current
max. 2 A (with UB 24 V)
Short-circuit proof
Yes
Output type
PNP- semiconductor
Output voltage
Operating voltage UB -0,5 V
Seperate output current
max. 0,6 mA (with UB 24 V)
Total output current
max. 2 A (with UB 24 V)
Short-circuit proof
Yes
General data
 
Memory card
Installation of a memory card MEM-SP-N-88-001-93 possible
Programming connection
Micro USB, Wireless Interface
Type terminal connection
clamp terminals
No-load current
82 mA with LED display

Mechanical data

Installation opening of buttons
22,5 mm

Equipment